NAME
hddtemp - Utility to monitor hard drive temperature
SYNOPSIS
hddtemp
[
options]
[[type:]disk]...
DESCRIPTION
hddtemp
will give you the temperature of your hard drive by reading
Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T.)
information on drives that support this feature. Only modern hard
drives have a temperature sensor. hddtemp supports reading S.M.A.R.T.
information from SCSI drives too.
hddtemp
can work as simple command line tool or as a daemon.
You can specify one or more device drive path, where each path can be prefixed
with a
type
like PATA, SATA or SCSI to force hddtemp too use one of these type
(because detection can fail). If no paths are specified, autodetection of
installed drives is attempted.
OPTIONS
The program follows the usual GNU command line syntax, with long
options starting with two dashes (`-'). A summary of options is
included below.
- -b, --drivebase
-
Display the database file that allows hddtemp to recognize a supported
drive.
- -D, --debug
-
Display various S.M.A.R.T. fields and their values. Useful for
finding a value that seems to match the temperature and/or to send a
report. (done for every drive supplied)
- -d, --daemon
-
Execute hddtemp in TCP/IP daemon mode (port 7634 by default).
- -f, --file=file
-
Specify the database file to use.
- -F, --foreground
-
Don't fork into the background even in daemon mode. This is useful
when running under a process supervisor.
- -l, --listen=addr
-
Listen on a specific address. addr is a string containing a
host name or a numeric host address string. The numeric host address
string is a dotted-decimal IPv4 address or an IPv6 hex address.
- -n, --numeric
-
Print only the temperature (without the unit).
- -p, --port=#
-
Port number to listen to (in TCP/IP daemon mode).
- -s, --separator=char
-
Separator to use between fields (in TCP/IP daemon mode). The default
separator is `|'.
- -S, --syslog=s
-
Switch to daemon mode and log temperatures to syslog every s
seconds.
- -q, --quiet
-
Don't check if the drive is supported.
- -u, --unit=C|F
-
Force output temperature either in Celsius or Fahrenheit.
- -v, --version
-
Display hddtemp version number.
- -w, --wake-up
-
Wake-up the drive if needed (ATA drives only).
- -4
-
Listen on IPv4 sockets only.
- -6
-
Listen on IPv6 sockets only.
DRIVE DATABASE
If you know your drive has a temperature sensor but it is being
reported unsupported, tell me which model and which manufacturer it
is, and/or just add a new entry in /usr/share/misc/hddtemp.db. Each
line of hddtemp.db is either a comment, a blank line or a line
containing:
- - a regular expression that allow hddtemp to recognize a drive or a
-
set of drives from its model name or from a generic model name,
- - a value (ATTRIBUTE_ID from S.M.A.R.T.),
-
- - a C or an F to set the unit to Celsius or Fahrenheit,
-
- - a description.
-
Feedback is welcome (see the REPORT section below).
TCP/IP DAEMON MODE
Example of type forcing:
# hddtemp SATA:/dev/sda PATA:/dev/hda
To test
hddtemp
in daemon mode, start it like this:
# hddtemp -d /dev/hd[abcd]
and use
telnet
or
netcat
(which is known as
nc
on some systems) to get a reply:
# netcat localhost 7634
The drive database is read only once at startup, so
hddtemp
must be restarted if the database is updated for the changes to take
effect.
REPORT
As I receive a lot of reports, things must be clarified. When
running hddtemp with debug options, hddtemp will show sort of a dump
of S.M.A.R.T. data. Each field corresponds to an information field.
The standard field for drive temperature is 194. But this is not
always the case (mostly for older drives). Even if your drive has
S.M.A.R.T. capabilities, it doesn't necessarily mean that it can
report its temperature. So, things must be determined through
experimentation.
So, you can try to guess which field by is the good one by running
hddtemp at regular intervals:
- just after starting up your PC/server/station,-
- after opening a window (a physical window :),-
- after opening the case,-
- whatever you can think of...-
and looking for a field's value that would increase or decrease
depending on what effect you want to induce. Be careful, fields 4, 9,
and 12 are often reported to match a temperature field but after some
investigation they do not. But fields 194 (which is the standard
field for temperature) and 231 are good candidates.
Then, you can send me a report with outputs from `hddtemp --debug ...',
`smartctl' or `hdparm -i ...', and/or add an entry in hddtemp.db
yourself.
BUGS
If hddtemp crashes (yes, it might) for some unknown reasons, look for
a file named hddtemp.backtrace.<PID>.XXXXXX (where XXXXXX is a random
number generated at runtime) in /tmp. Then, you can then send me this
file and the hddtemp binary. The backtrace functionality is currently
supported on i386 architectures only.
SEE ALSO
smartctl(8),
syslog(3),
syslogd(8).
AUTHOR
Emmanuel Varagnat (hddtemp@guzu.net).
This manual page was originally written by Aurelien Jarno <aurel32@debian.org>,
for the Debian GNU/Linux system (but may be used by others).